What kind of support do you need for a lavatory?
What kind of support do you need for a lavatory?
A lavatory is heavy. Provide suitable structural support behind the finished wall for the hanger lag screws. The wall, or whatever material the screws are attached to, must be of sufficient strength to fully support the lavatory. It may be necessary to install a 2 x 6 board behind the finished wall.
How big should a water closet be in front of a lavatory?
There shall be a clearance of not less than 21 inches (533 mm) in front of a water closet, or bidet to any wall, fixture or door. Lavatories. A lavatory shall not be set closer than 12 inches from its center to any side wall or partition.
How is a lavatory hung on a wall?
7The 1373 CORNATE corner lavatory is hung from the wall with two (2) smaller hangers. As with other lavatories, there must be suitable support behind the finished wall for the hanger screws. As illustrated in Figure 4 the lavatory is hung in the corner with one hanger on each wall.
Where does a laundry line connect to a standpipe?
Where a laundry tray waste line connects into a standpipe for an automatic clothes washer drain, the standpipe shall extend not less than 30 inches (762 mm) above the standpipe trap weir and shall extend above the flood level rim of the laundry tray.
Where does a lavatory have to be located in a public bathroom?
In employee and public toilet rooms, the required lavatory shall be located in the same room as the required water closet. Piping, fixtures or equipment shall not be located in such a manner as to interfere with the normal operation of windows, doors or other means of egress openings.
What do you need to know about the Plumbing Code?
The maximum water flow rates and flush volume for plumbing fixtures and fixture fittings shall comply with Section 604.4. Plumbing fixtures shall be constructed of approved materials, with smooth, impervious surfaces, free from defects and concealed fouling surfaces, and shall conform to standards cited in this code.
What do you need to know about being a plumbing inspector?
Plumbing inspectors spend time in an office setting, writing reports and recommendations, as well as in the field. Some risk may be associated with this career; plumbing inspectors typically are required to wear protective clothing and use gear such as goggles, earplugs, and/or gloves while working.
What’s the minimum weight for a plumbing fixture?
Sheet lead for pans shall not weigh less than 4 pounds per square foot (19.5 kg/m 2) coated with an asphalt paint or other approved coating. Plumbing fixtures shall be provided for the type of occupancy and in the minimum number shown in Table 403.1.